Peristaltic pump is a device that uses an elastic tube, also known as a hose pump or metering pump, to push liquid from one end to the other through periodic compression and relaxation of the tube. It is a common liquid transfer device in laboratories and has the characteristics of timed and quantitative transfer.
Peristaltic pumps for sale:
BT100
BT300
BT600
MOQ: 10 set.
Technical Specifications of Peristaltic Pump
– Speed: 0.1 to 600 rpm, reversible
– Speed precision: 0.1 rpm
– Speed control: Membrane keypad
– Display: 3-digit LED displays current rpm
– Communication interface: RS485
– External control: Start/stop, cw/ccw control and speed control 0-5 V, 0-10 V, 4-20 mA and 0-10KHz
– Power supply: AC 100V-240 V 50/60 Hz
– Power consumption: ≤20 W
– Operating condition: Temperature 0 to 40 ℃
– Relative humidity < 80%
– Dimensions (L×W×H): 232×142×149 (mm)
– Drive weight: 2.38 kg
– IP rating: IP 20
Feature of Peristaltic Pump
Sdlabio’s precision peristaltic pump can be installed with a variety of pump heads: YZ1515x, YZ2515x, YZⅡ15, YZⅡ25, BZ, DG, DG15, DMD15-13
- External control function: start and stop control, direction control, speed control (0-5V, 0-10V, 4-20mA, 0-10KHz optional)
- Full speed function: fast filling and emptying
- Speed regulation function: the speed can be adjusted manually or controlled through the external control interface
- Display function: display the current speed, direction and status
- Direction control: forward and reverse reversible
- Communication function: RS485 communication
Power-off memory function:
memory the working status before power-off (requires the working status to be maintained for more than 5 seconds)
For smaller volume pipetting needs, please use a micropipette or Pasteur pipette.
Lab Peristaltic pumps for Sale
| Type | Pump Head | Tubing | Max. Flow rate(ml/min) |
| BT100 | YZ1515x,YZII15 | 13# 14# 19# 16# 25# 17# 18# | 380 |
| YZ2515x,YZII25 | 15# 24# | 270 | |
| DG-(1、2) 6 roller | ID≤3.17mm, Wall T0.8-1mm | 48 | |
| DG-(1、2) 10 roller | ID≤3.17mm, Wall T0.8-1mm | 32 | |
| DG15-24 | 16# 25# 17# | 300 | |
| DG15-28 | 13# 14# ID≤3.17mm Wall thickness 0.8-1mm | 75 | |
| BZ15-13 | 14# 16# 25# 17# | 300 | |
| BZ25-13 | 24# | 300 | |
| DMD15-13 | 2*13# 2*14# 2*19# 2*16# 2*25# | 350 | |
| BT300 | YZ1515x,YZII15 | 13# 14# 19# 16# 25# 17# 18# | 1140 |
| YZ2515x | 15# 24# | 840 | |
| YZII25 | 15# 24# 35# 36# | 1500 | |
| DG15-24 | 16# 25# 17# | 900 (single channel) | |
| BT600 | YZ1515x,YZII15 | 13# 14# 19# 16# 25# 17# 18# | 2200 |
| YZ2515x | 15# 24# | 1600 | |
| YZII25 | 15# 24# 35# 36# | 3000 | |
| DG15-24 | 16# 25# 17# | 1800 (single channel) |
FAQ of Peristaltic Tube Pump
How do parastaltic pump work?
The working principle of a peristaltic metering pump: When the drive device is started, the compression element in the pump head begins to peristaltic motion. The peristaltic motion causes the compression element in the pump head to compress and relax periodically, thereby generating a series of peristaltic waves. These peristaltic waves propagate along the pipeline and push the liquid forward. The function of the valve is to control the flow direction of the liquid so that it can only flow in one direction.
How to use a peristaltic pump?
Based on the characters of the standard, the weighing apparatus required for the configuration of standard substance weighing is also very different.
Weighing paper: When the weighing volume is small, it is easily affected by buoyancy and static electricity, which may cause unstable weighing results. Suitable for solid weighing.
Weighing boat is suitable for small amount of solid and semi-solid weighing.
Pipette gun is a precision instrument with a certain range, suitable for liquid standards.
Micro syringes are suitable for micro liquid standards.
Different syringes are used for different raw material properties. For low boiling points and small surface tension of solvents, lock syringes should be used. Volatile liquids preferred incremental method of weighing.
How to calculate flow rate of peristaltic pump?
The flow calculation formula of the peristaltic pump is based on the working principle of its positive displacement pump, that is, a fixed flow output is generated for each revolution. By adjusting the speed, the required flow can be easily obtained. Generally, the flow calculation formula of the peristaltic pump can be expressed as:
Flow (L/min) = Peristaltic frequency (Hz) × Peristaltic amplitude (mm) × π × (Pipeline inner diameter (mm)/ 2)^2
Where π is pi. 1
In actual operation, the flow rate of the peristaltic pump at any speed can be measured, and then the flow rate at different speeds can be obtained by calculation. For example, using a 104KA/BT peristaltic pump and a 25# pump tube, when the speed is 300 rpm, the flow rate is 279ml/min. If a flow rate of 200ml/min is required, the required speed can be calculated:
First calculate the flow rate generated per revolution: 279ml/300 revolutions = 0.93ml/revolution
Then calculate the required speed: 200ml/0.93ml/revolution = 215.1 revolutions/minute. 2